Cold Shot Chillers 2 Ton model ACWC-24-Q water chillers are made in the USA and are among the most durable and dependable chillers on the market. We offer 2-ton chillers in air-cooled or water-cooled configurations. Stationary, portable, and reverse-flow designs are available to accommodate virtually any industrial process cooling applications.
2 Ton Air-cooled Chiller (Portable)
This air-cooled chiller features a hermetic scroll compressor and R410A refrigerant for reliable performance in industrial settings. An onboard PLC controls the system and displays alerts via error codes. Users adjust temperature with a simple LED controller. Built-in safeties protect against high/low temps, pressure issues, and fluid flow problems.
“Portable” means the air-cooled unit includes all key parts (compressor, reservoir, pump) within one frame. Most air-cooled portable chiller units will never be moved once installed.
Approximate weight: 563 lbs.
Dimensions: 42” L x 32.5” W x 51.5” H.
Standard Features
Controls: The unit comes standard with an electronically programmed temperature controller with constant (set point & process) temperature readout.
Refrigeration Components: Efficient scroll compressors, balanced port expansion valves, sight glass/moisture indicators, pump down valves, filter drier, fan cycling head pressure controls.
Process Fluid Components: Bronze “Y” strainer with 20 mesh stainless steel screen. Pumps are stainless steel centrifugal. Tanks are insulated with shoe box lid, fill port, and level sight glass. Portable systems will include a bypass flow valve.
Safety Controls: High and low refrigerant pressure, high and low fluid temperature, low water flow, thermal overloads for compressor and fan motors, safety fuses or overloads for pump.
Construction: Welded steel powder coated frame and full metal cabinet, copper piping connections.
Warranty: One year for parts / five year for the compressor.
2 Ton Air-cooled Chiller (Stationary)
“Stationary” means this chiller has no built-in pump or tank. It must connect to an external pump and reservoir.
Model ACWC-25-QST includes separate controls for the chiller and pump, with wiring recommended to ensure the chiller only runs when fluid is circulating. This air-cooled system uses a single-stage hermetic scroll compressor and R410A refrigerant. All wetted parts (tank, evaporator, and internal piping) are stainless steel or copper to resist corrosion.
Approximate weight: 550 lbs.
Dimensions: 42” L x 32.5” W x 51.5” H.
Standard Features
Controls: The unit comes standard with an electronically programmed temperature controller with constant (set point & process) temperature readout.
Refrigeration Components: Efficient scroll compressors, balanced port expansion valves, sight glass/moisture indicators, pump down valves, filter drier, fan cycling head pressure controls.
Process Fluid Components: Bronze “Y” strainer with 20 mesh stainless steel screen.
Safety Controls: High and low refrigerant pressure, high and low fluid temperature range, low water flow, thermal overloads for compressor and fan motors.
Construction: Welded steel powder coated frame and full metal cabinet, copper piping connections.
Warranty: One year for parts / five year for the compressor.
2 Ton Air-cooled Chiller (Reverse Flow)
The term “reverse flow” refers to a chiller that includes the refrigeration circuit, evaporator, and internal pumping system. The chiller is usually located near the customer’s external tank. Many of these applications are to chill an external tank to a predetermined temperature setting. The fluid is then pumped out to the customer’s process to remove heat from equipment. The warmed fluid is then pumped back to the external tank where the heat is exchanged by the chiller.
Our 2-ton air-cooled model ACWC-24-QRF approximate unit weight is 550 lbs. in total with dimensions of 42” L x 32 ½” W x 51 ½” H.
Standard Features
Controls: The unit comes standard with an electronic programmed temperature controller with constant (set point & process) temperature readout.
Refrigeration Components: Efficient scroll compressors, balanced port expansion valves, sight glass/moisture indicators, pump down valves, filter drier, fan cycling head pressure controls.
Process Fluid Components: Bronze “Y” strainer with 20 mesh stainless steel screen. Pumps are stainless steel centrifugal.
Safety Controls: High and low refrigerant pressure, high and low fluid temperature range, low water flow, thermal overloads for compressor and fan motors, safety fuses or overloads for pump.
Construction: Welded steel powder coated frame and full metal cabinet, copper piping connections.
Warranty: One year for parts / five year for the compressor.
2 Ton Water-cooled Units (Portable)
Model WCWC-24-Q is a 2-ton portable water-cooled chiller that removes up to 24,000 BTU/hr at 50°F leaving fluid and 85°F condensing water. It’s ideal for indoor use near the process, with low heat output.
It uses R-410A refrigerant and a hermetic scroll compressor for stable, efficient cooling. The unit works with building chilled water, ponds, lakes, or geothermal sources.
Dry weight: approx. 350 lbs.
Dimensions: 41” L x 29” W x 52” H. Built for long service life.
Standard Features
Controls: Electronically programmed temp. controller with a constant (set point & process) temperature readout.
Refrigeration Components: Efficient scroll compressors, sight glass/moisture indicators, balanced port expansion valves, filter drier, access ports and or service valves, pressure actuated head pressure controls, liquid receiver.
Process Fluid Components: Bronze “Y” strainer with 20 mesh stainless steel screen. Pumps are stainless steel centrifugal. Tanks are insulated with shoe box lid, fill port, and level sight glass. Portable systems will include a bypass flow valve.
Safety Controls: High and low refrigerant pressure controls, high and low fluid temperature, low water flow, thermal overloads for compressors, safety fuses or overloads for pump.
Construction: Welded steel powder-coated frame and full metal cabinet, copper piping connections, enclosure panels lift off for easy access
Warranty: One year parts / five year compressor.
2 Ton Water-cooled Chillers (Reverse Flow)
Cold Shot Chillers reverse flow chillers do not include tanks due to their use of an open loop cooling system. For applications of these types, an external tank is used to provide positive head pressure of water or heat transfer fluid to the system’s pump. The fluid is pumped from the external tank to the chiller and back to the tank. The heat from the fluid is transferred through the chiller’s evaporator, through the refrigeration system, and to the water-condensing heat evaporator.
Standard Features
Controls: Electronic programmed temperature controller with constant (set point & process) temperature readout.
Refrigeration Components: Efficient scroll compressors, sight glass/moisture indicators, balanced port expansion valves, filter drier, access ports and or service valves, pressure actuated head pressure controls, liquid receiver.
Process Fluid Components: Bronze “Y” strainer with 20 mesh stainless steel reservoir capacity. Pumps are stainless steel centrifugal. Tanks are insulated with shoe box lid, fill port, and level sight glass. Portable systems will include a bypass flow valve.
Safety Controls: High and low refrigerant pressure, high and low fluid temperature, low water flow, thermal overloads for compressors, safety fuses or overloads for pump.
Construction: Welded steel powder coated frame and full metal cabinet, copper piping connections.
* Capacity- 50°F LCWT/95°F AMB ** Capacity- 50°F LCWT/85°F CWT
Note: All specifications subject to change without notice. Specify Voltage and Ambient Condition upon ordering.
2 Ton Chiller Price
Pricing starts as low as $7,643.00. For pricing details or to discuss your industrial process cooling applications, contact us today.
Contact Cold Shot Chillers Today
Chiller performance depends on more than just tonnage. Unit cooling capacity, airflow layout, enclosure panels, and ambient temperatures all factor in. Cold Shot Chillers builds 2-ton air-cooled and water-cooled systems to match your exact specs.
Not sure which model or chiller capacity fits your job? We can help you:
Compare air-cooled air flow vs. water-cooled options
Match unit cooling capacity to your heat load
Choose enclosure panels for easy access and protection
Adjust for your site’s ambient temperatures
We’ll help you match specifications, model, and performance for reliable results.